Motors marked with Insulation Class B are suitable for use in ambient temperatures of up to ____ degrees Celsius.


A) 105
B) 130
C) 155
D) 180

E) C) and D)
F) A) and C)

Correct Answer

verifed

verified

The reason the Code uses the term ____ instead of motor is that, in many instances, the motor is inside an enclosure and is out of sight until an access panel is removed.


A) motor location
B) lock-out
C) start-stop
D) motor vicinity

E) B) and D)
F) A) and B)

Correct Answer

verifed

verified

For every ____ degree Celsius rise above the motor's rated temperature, the motor's insulation life is cut in half.


A) 5
B) 10
C) 32
D) 50

E) All of the above
F) A) and C)

Correct Answer

verifed

verified

A motor may be loaded continuously up to the horsepower obtained by multiplying the rated horsepower by the ____.


A) switch rating
B) ambient temperature
C) service factor
D) insulation rating

E) None of the above
F) B) and C)

Correct Answer

verifed

verified

Describe Type 2 short-circuit protection.

Correct Answer

verifed

verified

Type 2 short-circuit protection means th...

View Answer

An appliance is rated at 4500 volt-ampere, 240 volts, single-phase. What is the maximum size fuse permitted?


A) 20-ampere
B) 30-ampere
C) 40-ampere
D) 50-ampere

E) A) and D)
F) C) and D)

Correct Answer

verifed

verified

____ fuses are designed to withstand motor-starting inrush currents and will not open needlessly.


A) Ordinary
B) Branch-circuit
C) Dual-element, time-delay
D) Nontime-delay

E) A) and C)
F) B) and C)

Correct Answer

verifed

verified

C

In three-phase motors, each phase is ____ degrees out of phase (symmetrical) with the other phases.


A) 60
B) 90
C) 120
D) 360

E) None of the above
F) All of the above

Correct Answer

verifed

verified

When referring to motor controllers in the United States, we prefer to use the term ____ instead of coordination because coordination has a different meaning.


A) protection
B) isolation
C) breaking
D) service

E) A) and D)
F) All of the above

Correct Answer

verifed

verified

Color selection for ungrounded "hot" conductors can be just about any solid color except green, white, gray, or any color conductor (except ____) that has three continuous white stripes.


A) black
B) blue
C) red
D) green

E) B) and D)
F) B) and C)

Correct Answer

verifed

verified

D

____ is the most common cause of motor failure.


A) An open contact
B) Unbalanced voltage
C) Single phasing
D) Incorrect service factor

E) None of the above
F) All of the above

Correct Answer

verifed

verified

____ means the difference between motor winding temperature and the ambient temperature.


A) Operating temperature
B) Service factor
C) Overcurrent
D) Temperature rise

E) None of the above
F) B) and C)

Correct Answer

verifed

verified

NEMA rated motors are designed to operate at plus or minus ____ percent of their nameplate rated voltage.


A) 10
B) 20
C) 30
D) 40

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

A

For most applications, the motor circuit switch for a motor must be ____.


A) general-use
B) isolating
C) overcurrent
D) horsepower rated

E) None of the above
F) C) and D)

Correct Answer

verifed

verified

What is the relationship between the Code letter and starting current?

Correct Answer

verifed

verified

The higher the Code letter, the higher t...

View Answer

NEC 430.24 requires that the conductors supplying several motors, or a motor(s) and other load(s) , shall have an ampacity not less than ____ percent of the full-load current rating of the highest rated motor.


A) 75
B) 100
C) 125
D) 150

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

What are some possible causes of unbalanced voltage?

Correct Answer

verifed

verified

Unbalanced voltage may be caused by:
βˆ™...

View Answer

​What are some causes of motor failure?

Correct Answer

verifed

verified

Motor failures happen for many reasons. ...

View Answer

What is the minimum starting current for a 240-volt, 3-phase, Code letter J, 7-1/2-horsepower motor?


A) 114 amperes
B) 128 amperes
C) 132 amperes
D) 144 amperes

E) A) and B)
F) None of the above

Correct Answer

verifed

verified

What are the rules that govern air-conditioning and refrigerating equipment disconnect means?

Correct Answer

verifed

verified

​
Β It is required that the disconnecti...

View Answer