Filters
Question type

Study Flashcards

PVC bends must be made so that the conduit remains undamaged and the internal diameter of the conduit is ____.


A) not reduced
B) reduced by no more than one third
C) reduced by no more than one half
D) reduced by no more than two thirds

E) A) and C)
F) B) and C)

Correct Answer

verifed

verified

Rigid metal conduit (RMC) is a threadable raceway of ____ designed for the physical protection and routing of conductors and cables.


A) an incompressible material
B) circular cross section
C) galvanized steel
D) various bending radii

E) B) and C)
F) All of the above

Correct Answer

verifed

verified

Contact of dissimilar metals (except for the combination of aluminum and steel) should be avoided wherever possible to lessen the potential for ____.


A) galvanic action
B) inadvertent shorting
C) structural weakening
D) static charging

E) All of the above
F) C) and D)

Correct Answer

verifed

verified

A header is a transverse raceway ____.


A) that forms a continuous, unbroken conductor connecting individual outlets
B) in a cellular metal floor, that may be approved as enclosures for electric conductors
C) within rigid tubing enclosed in tubular space whose axis is parallel to the axis of a metal floor member
D) for electric conductors, providing access to predetermined cells of a cellular metal floor

E) A) and D)
F) A) and B)

Correct Answer

verifed

verified

Wireways are ____ housing and protecting electric wires (and cables) .


A) conductors for signaling circuits between a motor
B) troughs with hinged or removable covers for
C) ceiling fixtures connecting to luminaires or
D) current carrying junction boxes

E) A) and C)
F) B) and C)

Correct Answer

verifed

verified

Grounding conductors are required for circuits over ____ amperes.


A) 10
B) 20
C) 30
D) 40

E) B) and C)
F) All of the above

Correct Answer

verifed

verified

B

All cut ends of IMC and RMC must be ____.


A) anchored in a junction box
B) welded
C) color coded
D) reamed

E) A) and B)
F) C) and D)

Correct Answer

verifed

verified

Surface nonmetallic raceways and their fittings must be designed so that sections can be mechanically coupled together and installed without subjecting the wires to ____.


A) bending
B) abrasion
C) compression
D) tension

E) B) and C)
F) None of the above

Correct Answer

verifed

verified

The equivalent of ____ is the maximum allowed between pull points.


A) one quarter bends (90° total)
B) two half bends (180° total)
C) three quarter bends (270° total)
D) four quarter bends (360° total)

E) None of the above
F) A) and C)

Correct Answer

verifed

verified

A group of conductors that fit into one conduit may not fit into another type because the ____ of different types of conduit vary.


A) interfaces
B) spacing requirements
C) internal diameters
D) carrying capacity

E) All of the above
F) B) and D)

Correct Answer

verifed

verified

The minimum approved electrical trade size for EMT is ____ inches.


A) .15
B) .25
C) .5
D) .75

E) A) and B)
F) None of the above

Correct Answer

verifed

verified

Electric metal tubing (EMT) provides protection from ____.


A) all but severe physical damage
B) inadvertent grounding
C) water damage
D) lightening

E) B) and C)
F) B) and D)

Correct Answer

verifed

verified

NEC identifies ____ types of rigid PVC conduit.


A) two
B) three
C) five
D) ten

E) None of the above
F) B) and C)

Correct Answer

verifed

verified

C

Flexible metal conduit (FMC) is a raceway of circular cross section made of ____.


A) PVC laminated steel
B) helically wound, formed, and interlocked metal strips
C) concentrically wound aluminum alloy
D) interlocking metal and PVC conglomerate

E) C) and D)
F) A) and D)

Correct Answer

verifed

verified

B

Splices and taps are permitted within surface metal raceway having a removable cover that ____.


A) is accessible at another junction
B) contains a trap facility
C) contains a branch to a junction box
D) remains accessible after installation

E) B) and C)
F) A) and D)

Correct Answer

verifed

verified

Article 100 defines raceway as a(n) ____designed expressly for holding wires, cables, or busbars.


A) bracketed suspension system
B) enclosed channel of metallic (or nonmetallic) materials
C) polymer-based vertical conduit
D) metallic duct

E) A) and B)
F) C) and D)

Correct Answer

verifed

verified

Liquidtight flexible metal conduit (LFMC) is a raceway of circular cross section having a(n) ____ over an inner flexible metal core.


A) outer liquidtight, nonmetallic, sunlight-resistant jacket
B) inflexible PVC coating
C) immersible (water tight) surface
D) sunlight-resistant, rigid, metallic outer jacket

E) B) and C)
F) C) and D)

Correct Answer

verifed

verified

Underfloor raceway dead ends must be ____.


A) open
B) accessible
C) closed
D) non-accessible

E) A) and D)
F) B) and D)

Correct Answer

verifed

verified

Bends must be made so that the conduit or tubing remains undamaged with its internal diameter ____.


A) diminished by no more than a tenth
B) diminished by no more than half
C) diminished by no more than a third
D) basically undiminished

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Half-round and flat-top raceways not over 4 inches in width must be covered by ____ or more of concrete (or wood) .


A) .25 inches
B) .5 inches
C) .75 inches
D) one inch

E) A) and D)
F) None of the above

Correct Answer

verifed

verified

Showing 1 - 20 of 26

Related Exams

Show Answer